a-TroniX logo
a-TroniX logo
Accessories
AppCertificates
Configuration from A to Z
Control response timeController
Customer Specific
Devices
Boiler
Cloud
Energy Meter
Ev Charging Station
Gas Meter
Heat Pump
New integrations
Plc
Pv Hybrid And Battery Inverters
a-TroniXABB, FIMERADS-TecAforeAlphaESSAlpvoltAmpowrAngileAnklous PV, Hybrid and Battery InvertersAPsystemsAteps Battery
Autarco
BattlinkBeauventC-BatteryCellpowerChisageDanfossDeltaDET Power PV, Hybrid and Battery InvertersDEYEDiehl-AkoDMEGC InvertersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentESY InvertersEVEFairlandFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
LibattionMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRCT PowerRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H till SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Switched Loads
Water Meter
External Signals
InstallationLicenseNetworkQuick StartSafety, maintenance and legal noticesSpecificationsStatus LEDs
Troubleshooting
Wiring & connectivity guidelines
DevicesPv Hybrid And Battery Inverters
logo

Supported Devices

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Single Phase LV Hybrid Inverters (SG0XLP1-EU)SUN-3/3.6/5/6/7/7.6/8/10/12K❌✅❌
Three Phase LV Hybrid Inverters (SG0XLP3-EU)SUN-3/4/5/6/8/10/12/14/15/16/18/20K
Three Phase HV Hybrid Inverters (SG0XHP3-EU)SUN-5/6/8/10/12/15/20/25/29.9/30/35/40/50/60/70/75/80K
Single Phase String Inverters (G0XP1-EU)SUN-1/1.5/2/2.2/2.5/2.7/3/3.3/3.6/4/4.2/4.6/5/5.2/6/6.2/7/7.5/8/9/10/10.5K
Three Phase String Inverters (G0XP3-EU)SUN-3/4/5/6/7/8/9/10/12/15/18/20/22/23/25/30/35/36/40/45/50/60/70/75/80/90/100/120/125/130/135/136K

Wiring

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
Devicea-TroniX Controller model OM1a-TroniX Controller model IG8RS485-USB converterRS485-Ethernet converter
Pin 1 / Modbus-485_BRS485 ARS485_POSRS485 ATX+
Pin 2 / Modbus-485_ARS485 BRS485_NEGRS485 BTX-
Pin 3 / GND_485RS GNDGNDNot availableG
Image 1
Image 1
Image 1

Configuration

Warning
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the a-TroniX Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The a-TroniX Controller will scan on those first.

Go to “Main Screen” >> “System Settings” >> “Advanced Function.”

  • Modbus SN should be set to any number between 1 and 247. Do not select 0!! Note that if there are multiple devices on the RS485 bus, each should be given a unique number. This is the address.
  • Slave should be checked.
  • Only when an additional meter is connected directly to the inverter should “EX_meter For CT” be checked. If there is only a meter in parallel with the a-TroniX Controller it should be unchecked.
  • Make sure the following settings are all correct: "Max A Charge", "Max A Discharge", "Grid Charge Ampere"
Image 1
Last updated May 4, 2026Edit this page

DET Power PV, Hybrid and Battery Inverters

Previous Page

Diehl-Ako

Next Page

On this page

Supported DevicesWiringRS485Configuration